CDA21 min read

CDA Radiation Health and Safety (RHS) Practice Questions: 25 Questions and Answers

25 original DANB RHS-style practice questions on x-ray production, exposure factors, technique, image errors, processing and radiation protection, each with an explanation.

By Studencity Editorial Team · Published · Updated

cdaDANB RHS practice testdental radiography questionsCDA radiation health and safetydental x-ray errors
A dental assistant positioning an x-ray arm for a patient in a lead apron

25

Practice questions with explanations

4

Exposure factors compared

5

Rounds

In this article

Radiation Health and Safety is the CDA component that many dental assistants need first, because taking x-rays is part of the job in many offices. It tests whether you understand how the x-ray machine works, how to take a clear image the first time, and how to keep the dose to patients and yourself as low as possible.

This article starts with a table of the exposure factors, because so many RHS questions come back to them. Then come five rounds: x-ray production and biology, exposure factors and units, technique, image errors, and processing, digital imaging and protection.

Every question is an original practice item based on standard dental radiography principles, not a real exam question. Each explanation tells you why the answer is right and why the most tempting wrong option is wrong.

Quick takeaways

  • kVp controls beam quality and contrast; mA and exposure time control the quantity of x-rays and image density.
  • Too little vertical angulation elongates teeth; too much foreshortens them; wrong horizontal angulation overlaps contacts.
  • Protect patients with fast receptors, rectangular collimation and only the images they need, and protect yourself with distance, position and shielding.

The basics

What the RHS exam covers

The Radiation Health and Safety exam covers radiation physics and biology, the parts of the x-ray machine, exposure settings, intraoral and extraoral technique, image errors, film processing and digital imaging, quality assurance, infection control during radiography, and protection for patients and operators. Many states use RHS as part of their requirements for assistants who take x-rays. Check DANB's current RHS outline and your state dental board for what applies to you.

Keep this table in mind as you work through the questions. It explains most questions about images that are too light, too dark or lacking contrast.

FactorWhat it controlsIf you increase it
Kilovoltage peak (kVp)Beam quality: the energy and penetrating power of the x-raysThe beam penetrates more, the image gets darker, and contrast gets lower (more shades of gray)
Milliamperage (mA)Beam quantity: how many x-rays are producedMore x-rays are produced and the image gets darker
Exposure timeBeam quantity: how long x-rays are producedMore x-rays are produced, the image gets darker and patient dose rises
Source-to-receptor distanceBeam intensity at the receptor (inverse square law)Intensity falls, so the image gets lighter unless the exposure is increased

Round 1

X-ray production and radiation biology

Inside the tube head, a heated tungsten filament releases electrons that race to the tungsten target. These questions cover what happens there and what radiation does to living tissue.

  1. 1What metal is the target in the anode of a dental x-ray tube made of?

  2. 2When electrons strike the target, most of their energy is converted into:

  3. 3What is the purpose of aluminum filtration in the tube head?

  4. 4Most biological damage from dental x-rays happens through which process?

  5. 5Which cells are most sensitive to radiation?

Round 2

Exposure factors, image density and units

Use the table above. If a question asks about penetration or contrast, think kVp. If it asks about quantity or darkness, think mA and time. If it asks about distance, think inverse square law.

  1. 6With other settings unchanged, increasing the kVp produces:

  2. 7If the distance between the x-ray source and the receptor is doubled, the beam intensity at the receptor becomes:

  3. 8A film image is too light, and processing was correct. Which is a likely cause?

  4. 9Which SI unit is used to express effective dose and occupational dose limits?

  5. 10What is the maximum permissible annual dose for occupationally exposed workers in the US?

Round 3

Paralleling and bisecting technique

The paralleling technique is generally preferred because it gives less distortion. The bisecting technique is useful when anatomy, such as a shallow palate, makes parallel placement impossible.

  1. 11In the paralleling technique, how are the receptor and central ray positioned?

  2. 12Why is a longer source-to-receptor distance, such as a 16-inch PID, used with the paralleling technique?

  3. 13In the bisecting technique, the central ray is directed perpendicular to:

  4. 14Compared with a round PID, rectangular collimation:

  5. 15On a bitewing, the contacts between the premolars are overlapped. What caused this?

Round 4

Intraoral and panoramic image errors

A simple way to remember the vertical angulation errors: too little angle makes teeth too long (elongation), and too much angle makes teeth too short (foreshortening).

  1. 16The teeth on a periapical image look too short. What is the most likely cause?

  2. 17A film shows a curved, clear area with a sharp edge where part of the image is missing. What is this error?

  3. 18An intraoral image looks blurred throughout, with fuzzy outlines. What is the most likely cause?

  4. 19On a panoramic image, a dark shadow lies over the root tips of the maxillary teeth. What is the most likely cause?

  5. 20On a panoramic image, the occlusal plane curves up sharply into an exaggerated smile. How was the patient positioned?

Round 5

Processing, digital imaging and protection

The last round covers what happens after the exposure, and the habits that protect patients and staff every time an image is taken.

  1. 21In film processing, what does the fixer do?

  2. 22How far from the working surface should a darkroom safelight be?

  3. 23How should a digital sensor that can't be heat-sterilized be handled between patients?

  4. 24A young child can't hold the receptor in place. Who should hold it?

  5. 25How should the number and type of radiographs for a patient be decided?

Tip: DANB and CDA are registered trademarks of the Dental Assisting National Board, Inc. This article is an independent study aid and is not affiliated with or endorsed by DANB. Questions here are original practice items, not real exam questions.

Quick quiz: radiography basics

Five quick review questions. Tap an answer; each question locks after your first pick.

0 / 5 answered

  1. 1In labial mounting, which way does the embossed dot face?

  2. 2Which intraoral film speed is the fastest?

  3. 3What is the useful beam that comes out of the tube head called?

  4. 4What does a personal dosimeter badge measure?

  5. 5Which part of the tube head restricts the size and shape of the x-ray beam?

Frequently asked questions

What does the DANB RHS exam cover?

Radiation Health and Safety covers radiation physics and biology, the x-ray machine, exposure factors, intraoral and extraoral technique, image errors, processing and digital imaging, quality assurance, infection control in radiography, and patient and operator protection. Check DANB's current RHS content outline for the exact topics.

Do I need to pass RHS to take dental x-rays?

That depends on your state. Many states use the DANB RHS exam as part of their radiography requirements for dental assistants, while others have their own course or exam. Check your state dental board before you start taking x-rays.

What is the difference between the paralleling and bisecting techniques?

In paralleling, the receptor is parallel to the tooth's long axis and the central ray is perpendicular to both, which gives less distortion. In bisecting, the receptor sits against the tooth and the central ray is perpendicular to an imaginary line that bisects the angle between the receptor and the tooth.

How can I remember elongation and foreshortening?

Think of the angle and the length moving in opposite directions: too little vertical angle gives teeth that look too long (elongation), and too much vertical angle gives teeth that look too short (foreshortening).

What is a good way to practice for RHS?

Learn the exposure factor table and the common image errors first, since many questions come back to them, then practice mixed questions until you can explain each answer. CDA Exam Practice: Dental MCQ has a radiation safety group with explained answers, plus a daily quiz and timed quizzes.

Know the factors, the angles and the protections

Most RHS questions come back to a few ideas: what kVp, mA, time and distance do to the beam; how angulation and placement errors show on an image; and how ALARA shapes every choice from receptor speed to who holds the receptor. Master those, and the details have something to attach to.

  • Learn the exposure factor table until you can predict how each change affects an image.
  • Sketch each technique error and its cause on a single page and review it often.
  • Practice the radiation safety group in CDA Exam Practice: Dental MCQ until your scores are steady.

Check DANB and the source guidelines

DANB sets the eligibility pathways, content outlines and testing rules for the CDA and its component exams, and it updates them from time to time. Read the current exam page and candidate handbook on danb.org before you register or plan your study.

Use practice questions to find your weak topics, then go back to your dental assisting textbook, the CDC dental infection-control guidance and the OSHA Bloodborne Pathogens Standard to learn the reasoning behind each answer.

Sources and further reading

Keep reading