Radiation Health and Safety is the CDA component that many dental assistants need first, because taking x-rays is part of the job in many offices. It tests whether you understand how the x-ray machine works, how to take a clear image the first time, and how to keep the dose to patients and yourself as low as possible.
This article starts with a table of the exposure factors, because so many RHS questions come back to them. Then come five rounds: x-ray production and biology, exposure factors and units, technique, image errors, and processing, digital imaging and protection.
Every question is an original practice item based on standard dental radiography principles, not a real exam question. Each explanation tells you why the answer is right and why the most tempting wrong option is wrong.
Quick takeaways
- kVp controls beam quality and contrast; mA and exposure time control the quantity of x-rays and image density.
- Too little vertical angulation elongates teeth; too much foreshortens them; wrong horizontal angulation overlaps contacts.
- Protect patients with fast receptors, rectangular collimation and only the images they need, and protect yourself with distance, position and shielding.
The basics
What the RHS exam covers
The Radiation Health and Safety exam covers radiation physics and biology, the parts of the x-ray machine, exposure settings, intraoral and extraoral technique, image errors, film processing and digital imaging, quality assurance, infection control during radiography, and protection for patients and operators. Many states use RHS as part of their requirements for assistants who take x-rays. Check DANB's current RHS outline and your state dental board for what applies to you.
Keep this table in mind as you work through the questions. It explains most questions about images that are too light, too dark or lacking contrast.
| Factor | What it controls | If you increase it |
|---|---|---|
| Kilovoltage peak (kVp) | Beam quality: the energy and penetrating power of the x-rays | The beam penetrates more, the image gets darker, and contrast gets lower (more shades of gray) |
| Milliamperage (mA) | Beam quantity: how many x-rays are produced | More x-rays are produced and the image gets darker |
| Exposure time | Beam quantity: how long x-rays are produced | More x-rays are produced, the image gets darker and patient dose rises |
| Source-to-receptor distance | Beam intensity at the receptor (inverse square law) | Intensity falls, so the image gets lighter unless the exposure is increased |
Round 1
X-ray production and radiation biology
Inside the tube head, a heated tungsten filament releases electrons that race to the tungsten target. These questions cover what happens there and what radiation does to living tissue.
1What metal is the target in the anode of a dental x-ray tube made of?
Answer: Tungsten. The target is tungsten, which has a high melting point and a high atomic number, so it can withstand heat and produce x-rays efficiently. Copper is tempting because it is also part of the anode, but the copper stem's job is to carry heat away from the target.2When electrons strike the target, most of their energy is converted into:
Answer: Heat. About 99 percent of the electrons' energy becomes heat, and less than 1 percent becomes x-rays. X-rays are the tempting answer because they are the point of the machine, but the process is very inefficient, which is why heat control matters.3What is the purpose of aluminum filtration in the tube head?
Answer: To remove low-energy x-rays that add to patient dose but not to the image. Aluminum filters absorb the weak, long-wavelength x-rays that would be absorbed by the patient's skin without reaching the receptor. Shaping the beam is tempting because the filter and collimator sit close together, but restricting the beam's size and shape is the collimator's job.4Most biological damage from dental x-rays happens through which process?
Answer: The indirect effect, when radiation ionizes water and forms free radicals. The body is mostly water, so most damage comes from free radicals formed when radiation ionizes water molecules. The direct effect is tempting because DNA damage is what matters, but direct hits on critical molecules are much less common than indirect damage.5Which cells are most sensitive to radiation?
Answer: Lymphocytes and other rapidly dividing cells. Cells that divide quickly and are less specialized, such as lymphocytes, blood-forming cells and reproductive cells, are the most radiosensitive. Nerve cells are tempting because the nervous system seems delicate, but mature nerve and muscle cells are among the least radiosensitive.
Round 2
Exposure factors, image density and units
Use the table above. If a question asks about penetration or contrast, think kVp. If it asks about quantity or darkness, think mA and time. If it asks about distance, think inverse square law.
6With other settings unchanged, increasing the kVp produces:
Answer: A more penetrating beam and lower contrast, with more shades of gray. Higher kVp produces higher-energy x-rays that penetrate more, giving a darker image with many shades of gray (long-scale, low contrast). Higher contrast is the tempting choice, but that comes from lower kVp, which produces mostly blacks and whites.7If the distance between the x-ray source and the receptor is doubled, the beam intensity at the receptor becomes:
Answer: One quarter of what it was. Under the inverse square law, intensity changes with the square of the distance, so doubling the distance cuts intensity to 1/2 × 1/2 = 1/4. One half is tempting because the distance only doubled, but the beam spreads over an area that grows with the square of the distance.8A film image is too light, and processing was correct. Which is a likely cause?
Answer: The exposure time was too short. Too little exposure time, or too little mA, means too few x-rays reached the film, so it comes out light. A long exposure is tempting because exposure problems are being asked about, but too much exposure makes the image too dark, and light leaks also darken film.9Which SI unit is used to express effective dose and occupational dose limits?
Answer: Sievert (Sv). The sievert is the SI unit for equivalent and effective dose, which take into account the type of radiation and the tissues exposed, so dose limits use it. The gray is tempting because it is also an SI dose unit, but it measures absorbed dose, the energy deposited in tissue.10What is the maximum permissible annual dose for occupationally exposed workers in the US?
Answer: 50 mSv (5 rem). The annual limit for occupationally exposed adults is 50 millisieverts, or 5 rem, of whole-body effective dose. 5 mSv is tempting because it is one-tenth of the limit, but it isn't the limit; the limit for members of the public is lower still, at 1 mSv a year, and the goal under ALARA is to stay far below any limit.
Round 3
Paralleling and bisecting technique
The paralleling technique is generally preferred because it gives less distortion. The bisecting technique is useful when anatomy, such as a shallow palate, makes parallel placement impossible.
11In the paralleling technique, how are the receptor and central ray positioned?
Answer: Receptor parallel to the tooth's long axis, central ray perpendicular to both. Paralleling places the receptor parallel to the long axis of the tooth and directs the central ray at right angles to both, which keeps distortion low. The option with the imaginary bisector is tempting because it is also a real technique, but it describes bisecting, not paralleling.12Why is a longer source-to-receptor distance, such as a 16-inch PID, used with the paralleling technique?
Answer: To offset the magnification caused by placing the receptor farther from the tooth. To keep the receptor parallel to the tooth, it must sit away from the tooth, which magnifies and blurs the image; a longer target distance uses straighter rays to reduce this. A more penetrating beam is tempting, but penetration depends on kVp, not on PID length.13In the bisecting technique, the central ray is directed perpendicular to:
Answer: An imaginary line bisecting the angle between the receptor and the tooth's long axis. The bisecting technique is based on the rule of isometry: aim the ray at right angles to the imaginary line that splits the angle between the receptor and the tooth. The tooth's long axis is tempting, but aiming perpendicular to it instead of the bisector would make the image elongated.14Compared with a round PID, rectangular collimation:
Answer: Reduces the area of tissue exposed, lowering patient dose. A rectangular collimator shapes the beam to roughly the size of the receptor, so much less tissue is exposed. Saying it makes cone cuts impossible is tempting, but a smaller beam actually needs more careful alignment, so cone cuts are easier to make if the PID is off center.15On a bitewing, the contacts between the premolars are overlapped. What caused this?
Answer: Incorrect horizontal angulation. Overlapped contacts mean the central ray wasn't directed straight through the spaces between the teeth, which is a horizontal angulation error. Vertical angulation is tempting because it is the other angle you set, but vertical errors stretch or shorten teeth rather than overlapping them.
Round 4
Intraoral and panoramic image errors
A simple way to remember the vertical angulation errors: too little angle makes teeth too long (elongation), and too much angle makes teeth too short (foreshortening).
16The teeth on a periapical image look too short. What is the most likely cause?
Answer: Too much vertical angulation. Foreshortening, where teeth look shorter than they are, comes from excessive vertical angulation. Too little vertical angulation is the tempting answer because it is the same kind of error, but it has the opposite effect and makes teeth look too long.17A film shows a curved, clear area with a sharp edge where part of the image is missing. What is this error?
Answer: Cone cut. A cone cut happens when the PID isn't centered over the receptor, so part of the film gets no x-rays and stays clear (white once viewed). Reversed film is tempting because it also makes the image light, but it lightens the whole image and adds a pattern rather than cutting off one area.18An intraoral image looks blurred throughout, with fuzzy outlines. What is the most likely cause?
Answer: The patient, receptor or tube head moved during exposure. Movement during the exposure smears every outline, giving a blurred image. Double exposure is tempting because it can look confusing too, but it produces two separate, overlapping images, each with sharp outlines.19On a panoramic image, a dark shadow lies over the root tips of the maxillary teeth. What is the most likely cause?
Answer: The patient's tongue wasn't placed against the roof of the mouth. If the tongue isn't held against the palate, the air space between the tongue and palate shows as a dark (radiolucent) shadow over the maxillary apices. A raised chin is tempting because it is a common panoramic error, but it flattens or reverses the curve of the occlusal plane rather than causing this shadow.20On a panoramic image, the occlusal plane curves up sharply into an exaggerated smile. How was the patient positioned?
Answer: The chin was tipped too far down. Tipping the chin down produces an exaggerated upward curve, often called a smile, and can blur the lower incisors. Chin up is the tempting answer because it is the matching error, but it flattens the curve or turns it into a frown.
Round 5
Processing, digital imaging and protection
The last round covers what happens after the exposure, and the habits that protect patients and staff every time an image is taken.
21In film processing, what does the fixer do?
Answer: Removes unexposed silver halide crystals and hardens the emulsion. The fixer clears away the unexposed, undeveloped crystals so the image is permanent, and it hardens the emulsion. Turning exposed crystals into black silver is tempting because it is a key step, but that is the developer's job.22How far from the working surface should a darkroom safelight be?
Answer: At least 4 feet. A safelight with the right filter and bulb still fogs film if it is too close, so it should be at least 4 feet from where films are unwrapped. Saying distance doesn't matter is tempting because the filter makes the light safe, but the filter only works within its limits of distance and time.23How should a digital sensor that can't be heat-sterilized be handled between patients?
Answer: Cover it with an FDA-cleared barrier, then clean and disinfect it per the manufacturer. CDC guidance is to protect sensors with an FDA-cleared barrier and, after each patient, clean and disinfect or sterilize them as the manufacturer directs. Autoclaving is tempting because sensors are semicritical, but most sensors can't tolerate heat, which is why barriers and the manufacturer's instructions matter.24A young child can't hold the receptor in place. Who should hold it?
Answer: A parent or caregiver wearing a lead or lead-equivalent apron. If a receptor must be held, a parent or caregiver should do it while protected by an apron. The assistant is tempting because they are trained, but operators must never hold receptors or patients during exposures, since they would receive repeated doses day after day.25How should the number and type of radiographs for a patient be decided?
Answer: By the dentist, based on the patient's needs after a clinical exam. ADA and FDA guidance says radiographs should be prescribed by the dentist based on each patient's history, clinical exam and risk, not taken on a routine schedule. A fixed yearly series is tempting because it seems thorough, but it would expose some patients to radiation they don't need.
Tip: DANB and CDA are registered trademarks of the Dental Assisting National Board, Inc. This article is an independent study aid and is not affiliated with or endorsed by DANB. Questions here are original practice items, not real exam questions.
Quick quiz: radiography basics
Five quick review questions. Tap an answer; each question locks after your first pick.
0 / 5 answered
1In labial mounting, which way does the embossed dot face?
Answer: Toward the viewer (raised). In labial mounting, recommended by the ADA, the raised side of the dot faces you, so you view the images as if you were facing the patient.2Which intraoral film speed is the fastest?
Answer: F-speed. F-speed film needs less exposure than D- or E-speed film for the same image, which lowers patient dose.3What is the useful beam that comes out of the tube head called?
Answer: Primary radiation. Primary radiation is the useful beam. Secondary and scatter radiation form when the primary beam interacts with matter, such as the patient's tissues.4What does a personal dosimeter badge measure?
Answer: The radiation dose the wearer receives at work. A dosimeter records the occupational dose received by the person wearing it, helping the office confirm that doses stay low.5Which part of the tube head restricts the size and shape of the x-ray beam?
Answer: The collimator. The collimator, a lead plate with an opening, restricts the beam's size and shape. The aluminum filter removes low-energy x-rays.
Frequently asked questions
What does the DANB RHS exam cover?
Radiation Health and Safety covers radiation physics and biology, the x-ray machine, exposure factors, intraoral and extraoral technique, image errors, processing and digital imaging, quality assurance, infection control in radiography, and patient and operator protection. Check DANB's current RHS content outline for the exact topics.
Do I need to pass RHS to take dental x-rays?
That depends on your state. Many states use the DANB RHS exam as part of their radiography requirements for dental assistants, while others have their own course or exam. Check your state dental board before you start taking x-rays.
What is the difference between the paralleling and bisecting techniques?
In paralleling, the receptor is parallel to the tooth's long axis and the central ray is perpendicular to both, which gives less distortion. In bisecting, the receptor sits against the tooth and the central ray is perpendicular to an imaginary line that bisects the angle between the receptor and the tooth.
How can I remember elongation and foreshortening?
Think of the angle and the length moving in opposite directions: too little vertical angle gives teeth that look too long (elongation), and too much vertical angle gives teeth that look too short (foreshortening).
What is a good way to practice for RHS?
Learn the exposure factor table and the common image errors first, since many questions come back to them, then practice mixed questions until you can explain each answer. CDA Exam Practice: Dental MCQ has a radiation safety group with explained answers, plus a daily quiz and timed quizzes.
Know the factors, the angles and the protections
Most RHS questions come back to a few ideas: what kVp, mA, time and distance do to the beam; how angulation and placement errors show on an image; and how ALARA shapes every choice from receptor speed to who holds the receptor. Master those, and the details have something to attach to.
- Learn the exposure factor table until you can predict how each change affects an image.
- Sketch each technique error and its cause on a single page and review it often.
- Practice the radiation safety group in CDA Exam Practice: Dental MCQ until your scores are steady.
Check DANB and the source guidelines
DANB sets the eligibility pathways, content outlines and testing rules for the CDA and its component exams, and it updates them from time to time. Read the current exam page and candidate handbook on danb.org before you register or plan your study.
Use practice questions to find your weak topics, then go back to your dental assisting textbook, the CDC dental infection-control guidance and the OSHA Bloodborne Pathogens Standard to learn the reasoning behind each answer.
Sources and further reading